Grounding Disconnector

General Information

ARM-TP-1kA type earthing disconnectors used in AS36 LF series 36kV 16kA 630A + fuse combination transformer protection switchgears produced within EFG ELEKTRIK are designed in accordance with the standards. Necessary type tests of this separator have been carried out in international and national laboratories. E2 class type-tested earthing disconnectors prevent the personnel in front of the cubicle from being harmed, thanks to their 5 closing feature in short circuit. Earthing disconnectors are produced as 3-pole in accordance with TS EN 62271-102 standard.

TYPEAS-1AS-16AES36F
RATED VOLTAGE36 kV24 kV36 kV
RATED SHORT-TERM WITHDRAWN CURRENT1 kA16 kA1 kA
RATED PEAK STRENGTH CURRENT2,5 kA40 kA2,5 kA
RATED SHORT CIRCUIT TIME1 sec.1 sec.1 sec.
CLASSE2E2E2
APPLIED STANDARDTS EN 62271-102TS EN 62271-102TS EN 62271-102

 

Contact For Detailed Information About The Product