General Information
ARM-TP-1kA type earthing disconnectors used in AS36 LF series 36kV 16kA 630A + fuse combination transformer protection switchgears produced within EFG ELEKTRIK are designed in accordance with the standards. Necessary type tests of this separator have been carried out in international and national laboratories. E2 class type-tested earthing disconnectors prevent the personnel in front of the cubicle from being harmed, thanks to their 5 closing feature in short circuit. Earthing disconnectors are produced as 3-pole in accordance with TS EN 62271-102 standard.
TYPE | AS-1 | AS-16 | AES36F |
RATED VOLTAGE | 36 kV | 24 kV | 36 kV |
RATED SHORT-TERM WITHDRAWN CURRENT | 1 kA | 16 kA | 1 kA |
RATED PEAK STRENGTH CURRENT | 2,5 kA | 40 kA | 2,5 kA |
RATED SHORT CIRCUIT TIME | 1 sec. | 1 sec. | 1 sec. |
CLASS | E2 | E2 | E2 |
APPLIED STANDARD | TS EN 62271-102 | TS EN 62271-102 | TS EN 62271-102 |